Normal Usage
- Turn probe on (Green light should come on)
 - Log into QC
 - Any form with a temperature sample control should cause the light on the probe to flash quickly for a few seconds. Leaving and reentering the form will cause QC to reattempt to contact the probe.
 
QC Form Setup
- Add sample control to your form
 - Change Equipment Type to "Temperature"
 - If a specific probe is required, enter the devices QC serial number into the Serial Number field.
 
Initial Setup for Windows Mobile
- Turn Probe on
 - Goto Settings>>Connections>>Bluetooth
 - Click “Add new device”
 - Follow the steps in the wizard. When asked, the Passkey is 004321
 - Click on the Intelliprobe in the Bluetooth devices list.
 - Check the box “Serial Port” under Services to use
 - Click “Save”
 - Click on the “Com Ports” tab
 - Click “New outgoing Port”
 - Pick a com port (above 7 works better since several of them are used internally by most Handhelds)